YANG Alarm Module
draft-ietf-ccamp-alarm-module-06

Document Type Active Internet-Draft (ccamp WG)
Last updated 2018-11-21
Replaces draft-vallin-ccamp-alarm-module
Stream IETF
Intended RFC status (None)
Formats plain text pdf html bibtex
Yang Validation 0 errors, 0 warnings.
Reviews
Additional URLs
- Yang catalog entry for ietf-alarms-x733@2018-11-22.yang
- Yang catalog entry for ietf-alarms@2018-11-22.yang
- Yang impact analysis for draft-ietf-ccamp-alarm-module
- Mailing list discussion
Stream WG state In WG Last Call
Document shepherd No shepherd assigned
IESG IESG state I-D Exists
Consensus Boilerplate Unknown
Telechat date
Responsible AD (None)
Send notices to (None)
Network Working Group                                          S. Vallin
Internet-Draft                                          Stefan Vallin AB
Intended status: Standards Track                            M. Bjorklund
Expires: May 26, 2019                                              Cisco
                                                       November 22, 2018

                           YANG Alarm Module
                    draft-ietf-ccamp-alarm-module-06

Abstract

   This document defines a YANG module for alarm management.  It
   includes functions for alarm list management, alarm shelving and
   notifications to inform management systems.  There are also
   operations to manage the operator state of an alarm and
   administrative alarm procedures.  The module carefully maps to
   relevant alarm standards.

Status of This Memo

   This Internet-Draft is submitted in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF).  Note that other groups may also distribute
   working documents as Internet-Drafts.  The list of current Internet-
   Drafts is at http://datatracker.ietf.org/drafts/current/.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   This Internet-Draft will expire on May 26, 2019.

Copyright Notice

   Copyright (c) 2018 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of

Vallin & Bjorklund        Expires May 26, 2019                  [Page 1]
Internet-Draft              YANG Alarm Module              November 2018

   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Table of Contents

   1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   3
     1.1.  Terminology and Notation  . . . . . . . . . . . . . . . .   3
   2.  Objectives  . . . . . . . . . . . . . . . . . . . . . . . . .   4
   3.  Alarm Module Concepts . . . . . . . . . . . . . . . . . . . .   5
     3.1.  Alarm Definition  . . . . . . . . . . . . . . . . . . . .   5
     3.2.  Alarm Type  . . . . . . . . . . . . . . . . . . . . . . .   5
     3.3.  Identifying the Alarming Resource . . . . . . . . . . . .   7
     3.4.  Identifying Alarm Instances . . . . . . . . . . . . . . .   8
     3.5.  Alarm Life-Cycle  . . . . . . . . . . . . . . . . . . . .   8
       3.5.1.  Resource Alarm Life-Cycle . . . . . . . . . . . . . .   9
       3.5.2.  Operator Alarm Life-cycle . . . . . . . . . . . . . .  10
       3.5.3.  Administrative Alarm Life-Cycle . . . . . . . . . . .  10
     3.6.  Root Cause, Impacted Resources and Related Alarms . . . .  10
     3.7.  Alarm Shelving  . . . . . . . . . . . . . . . . . . . . .  11
     3.8.  Alarm Profiles  . . . . . . . . . . . . . . . . . . . . .  12
   4.  Alarm Data Model  . . . . . . . . . . . . . . . . . . . . . .  12
     4.1.  Alarm Control . . . . . . . . . . . . . . . . . . . . . .  14
       4.1.1.  Alarm Shelving  . . . . . . . . . . . . . . . . . . .  14
     4.2.  Alarm Inventory . . . . . . . . . . . . . . . . . . . . .  14
     4.3.  Alarm Summary . . . . . . . . . . . . . . . . . . . . . .  15
     4.4.  The Alarm List  . . . . . . . . . . . . . . . . . . . . .  16
     4.5.  The Shelved Alarms List . . . . . . . . . . . . . . . . .  18
     4.6.  Alarm Profiles  . . . . . . . . . . . . . . . . . . . . .  18
     4.7.  Operations  . . . . . . . . . . . . . . . . . . . . . . .  19
     4.8.  Notifications . . . . . . . . . . . . . . . . . . . . . .  19
   5.  Relationship to the ietf-hardware YANG module . . . . . . . .  19
   6.  Alarm YANG Module . . . . . . . . . . . . . . . . . . . . . .  20
   7.  X.733 Extensions  . . . . . . . . . . . . . . . . . . . . . .  50
   8.  The X.733 Mapping Module  . . . . . . . . . . . . . . . . . .  51
   9.  IANA Considerations . . . . . . . . . . . . . . . . . . . . .  62
   10. Security Considerations . . . . . . . . . . . . . . . . . . .  63
   11. Acknowledgements  . . . . . . . . . . . . . . . . . . . . . .  64
   12. References  . . . . . . . . . . . . . . . . . . . . . . . . .  64
     12.1.  Normative References . . . . . . . . . . . . . . . . . .  64
     12.2.  Informative References . . . . . . . . . . . . . . . . .  65
   Appendix A.  Vendor-specific Alarm-Types Example  . . . . . . . .  66
Show full document text