A YANG Data Model for Alarm Management
RFC 8632

Document Type RFC - Proposed Standard (September 2019; No errata)
Last updated 2019-09-11
Replaces draft-vallin-ccamp-alarm-module
Stream IETF
Formats plain text html pdf htmlized bibtex
Yang Validation 0 errors, 0 warnings.
Reviews
Additional URLs
- Yang catalog entry for ietf-alarms-x733@2019-03-21.yang
- Yang catalog entry for ietf-alarms@2019-04-10.yang
- Yang impact analysis for draft-ietf-ccamp-alarm-module
- Mailing list discussion
Stream WG state Submitted to IESG for Publication
Document shepherd Daniele Ceccarelli
Shepherd write-up Show (last changed 2019-01-09)
IESG IESG state RFC 8632 (Proposed Standard)
Consensus Boilerplate Yes
Telechat date
Responsible AD Deborah Brungard
Send notices to Daniele Ceccarelli <daniele.ceccarelli@ericsson.com>
IANA IANA review state Version Changed - Review Needed
IANA action state RFC-Ed-Ack
Internet Engineering Task Force (IETF)                         S. Vallin
Request for Comments: 8632                              Stefan Vallin AB
Category: Standards Track                                   M. Bjorklund
ISSN: 2070-1721                                                    Cisco
                                                          September 2019

                 A YANG Data Model for Alarm Management

Abstract

   This document defines a YANG module for alarm management.  It
   includes functions for alarm-list management, alarm shelving, and
   notifications to inform management systems.  There are also
   operations to manage the operator state of an alarm and
   administrative alarm procedures.  The module carefully maps to
   relevant alarm standards.

Status of This Memo

   This is an Internet Standards Track document.

   This document is a product of the Internet Engineering Task Force
   (IETF).  It represents the consensus of the IETF community.  It has
   received public review and has been approved for publication by the
   Internet Engineering Steering Group (IESG).  Further information on
   Internet Standards is available in Section 2 of RFC 7841.

   Information about the current status of this document, any errata,
   and how to provide feedback on it may be obtained at
   https://www.rfc-editor.org/info/rfc8632.

Copyright Notice

   Copyright (c) 2019 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (https://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Vallin & Bjorklund           Standards Track                    [Page 1]
RFC 8632         A YANG Data Model for Alarm Management   September 2019

Table of Contents

   1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   3
     1.1.  Terminology and Notation  . . . . . . . . . . . . . . . .   3
   2.  Objectives  . . . . . . . . . . . . . . . . . . . . . . . . .   5
   3.  Alarm Data Model Concepts . . . . . . . . . . . . . . . . . .   5
     3.1.  Alarm Definition  . . . . . . . . . . . . . . . . . . . .   5
     3.2.  Alarm Type  . . . . . . . . . . . . . . . . . . . . . . .   6
     3.3.  Identifying the Alarming Resource . . . . . . . . . . . .   8
     3.4.  Identifying Alarm Instances . . . . . . . . . . . . . . .   9
     3.5.  Alarm Lifecycle . . . . . . . . . . . . . . . . . . . . .   9
       3.5.1.  Resource Alarm Lifecycle  . . . . . . . . . . . . . .  10
       3.5.2.  Operator Alarm Lifecycle  . . . . . . . . . . . . . .  11
       3.5.3.  Administrative Alarm Lifecycle  . . . . . . . . . . .  11
     3.6.  Root Cause, Impacted Resources, and Related Alarms  . . .  11
     3.7.  Alarm Shelving  . . . . . . . . . . . . . . . . . . . . .  13
     3.8.  Alarm Profiles  . . . . . . . . . . . . . . . . . . . . .  13
   4.  Alarm Data Model  . . . . . . . . . . . . . . . . . . . . . .  13
     4.1.  Alarm Control . . . . . . . . . . . . . . . . . . . . . .  15
       4.1.1.  Alarm Shelving  . . . . . . . . . . . . . . . . . . .  15
     4.2.  Alarm Inventory . . . . . . . . . . . . . . . . . . . . .  16
     4.3.  Alarm Summary . . . . . . . . . . . . . . . . . . . . . .  16
     4.4.  The Alarm List  . . . . . . . . . . . . . . . . . . . . .  17
     4.5.  The Shelved-Alarm List  . . . . . . . . . . . . . . . . .  19
     4.6.  Alarm Profiles  . . . . . . . . . . . . . . . . . . . . .  19
     4.7.  Operations  . . . . . . . . . . . . . . . . . . . . . . .  20
     4.8.  Notifications . . . . . . . . . . . . . . . . . . . . . .  20
   5.  Relationship to the ietf-hardware YANG Module . . . . . . . .  20
   6.  Alarm YANG Module . . . . . . . . . . . . . . . . . . . . . .  21
   7.  The X.733 Mapping Module  . . . . . . . . . . . . . . . . . .  53
   8.  IANA Considerations . . . . . . . . . . . . . . . . . . . . .  65
   9.  Security Considerations . . . . . . . . . . . . . . . . . . .  65
   10. References  . . . . . . . . . . . . . . . . . . . . . . . . .  67
     10.1.  Normative References . . . . . . . . . . . . . . . . . .  67
     10.2.  Informative References . . . . . . . . . . . . . . . . .  68
   Appendix A.  Vendor-Specific Alarm Types Example  . . . . . . . .  70
   Appendix B.  Alarm Inventory Example  . . . . . . . . . . . . . .  71
   Appendix C.  Alarm List Example . . . . . . . . . . . . . . . . .  71
   Appendix D.  Alarm Shelving Example . . . . . . . . . . . . . . .  73
   Appendix E.  X.733 Mapping Example  . . . . . . . . . . . . . . .  74