Skip to main content

Redundancy Mechanism for Inter-domain VPLS Service
draft-ietf-l2vpn-vpls-inter-domain-redundancy-06

The information below is for an old version of the document.
Document Type
This is an older version of an Internet-Draft that was ultimately published as RFC 7309.
Authors Zhihua Liu , Lizhong Jin , Ran Chen , Dennis Cai , Samer Salam
Last updated 2014-05-15 (Latest revision 2014-04-24)
Replaces draft-liu-l2vpn-vpls-inter-domain-redundancy
RFC stream Internet Engineering Task Force (IETF)
Formats
Reviews
Additional resources Mailing list discussion
Stream WG state Submitted to IESG for Publication
Document shepherd Giles Heron
Shepherd write-up Show Last changed 2014-05-14
IESG IESG state Became RFC 7309 (Proposed Standard)
Consensus boilerplate Yes
Telechat date (None)
Responsible AD Adrian Farrel
Send notices to l2vpn-chairs@tools.ietf.org, draft-ietf-l2vpn-vpls-inter-domain-redundancy@tools.ietf.org
IANA IANA review state IANA OK - No Actions Needed
draft-ietf-l2vpn-vpls-inter-domain-redundancy-06
Networking Working Group                                          Z. Liu
Internet-Draft                                             China Telecom
Intended status: Standards Track                                  L. Jin
Expires: October 26, 2014
                                                                 R. Chen
                                                         ZTE Corporation
                                                                  D. Cai
                                                                S. Salam
                                                                   Cisco
                                                          April 24, 2014

           Redundancy Mechanism for Inter-domain VPLS Service
            draft-ietf-l2vpn-vpls-inter-domain-redundancy-06

Abstract

   In many existing Virtual Private LAN Service (VPLS) inter-domain
   deployments (based on RFC 4762), pseudowire (PW) connectivity offers
   no node redundancy, or offers node redundancy only with a single
   domain.  This deployment approach incurs a high risk of service
   interruption, since at least one domain will not offer PW node
   redundancy.  This document describes an inter-domain VPLS solution
   that provides PW node redundancy across domains.

Status of this Memo

   This Internet-Draft is submitted in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF).  Note that other groups may also distribute
   working documents as Internet-Drafts.  The list of current Internet-
   Drafts is at http://datatracker.ietf.org/drafts/current/.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   This Internet-Draft will expire on October 26, 2014.

Copyright Notice

   Copyright (c) 2014 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal

Liu, et al.             Expires October 26, 2014                [Page 1]
Internet-Draft      Redundancy for VPLS Inter-domain          April 2014

   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Table of Contents

   1.  Introduction . . . . . . . . . . . . . . . . . . . . . . . . .  3
   2.  Conventions used in this document  . . . . . . . . . . . . . .  3
   3.  Motivation . . . . . . . . . . . . . . . . . . . . . . . . . .  3
   4.  Network Use Case . . . . . . . . . . . . . . . . . . . . . . .  4
   5.  PW redundancy application procedure for inter-domain
       redundancy . . . . . . . . . . . . . . . . . . . . . . . . . .  6
     5.1.  ICCP switchover condition  . . . . . . . . . . . . . . . .  6
       5.1.1.  Inter-domain PW failure  . . . . . . . . . . . . . . .  6
       5.1.2.  PE node isolation  . . . . . . . . . . . . . . . . . .  6
       5.1.3.  PE node failure  . . . . . . . . . . . . . . . . . . .  6
     5.2.  Inter-domain redundancy with two-PWs . . . . . . . . . . .  6
     5.3.  Inter-domain redundancy with four-PWs  . . . . . . . . . .  7
   6.  Management Considerations  . . . . . . . . . . . . . . . . . .  9
   7.  Security Considerations  . . . . . . . . . . . . . . . . . . .  9
   8.  IANA Consideration . . . . . . . . . . . . . . . . . . . . . .  9
   9.  Acknowledgements . . . . . . . . . . . . . . . . . . . . . . .  9
   10. Contributors . . . . . . . . . . . . . . . . . . . . . . . . . 10
   11. References . . . . . . . . . . . . . . . . . . . . . . . . . . 10
     11.1. Normative references . . . . . . . . . . . . . . . . . . . 10
     11.2. Informative references . . . . . . . . . . . . . . . . . . 10
   Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . . 11

Liu, et al.             Expires October 26, 2014                [Page 2]
Internet-Draft      Redundancy for VPLS Inter-domain          April 2014

1.  Introduction

   In many existing Virtual Private LAN Service (VPLS) deployments based
   on [RFC4762], pseudowire (PW) connectivity offers no node redundancy,
   or offers node redundancy only with a single domain.  This deployment
   approach incurs a high risk of service interruption, since at least
   one domain will not offer PW node redundancy.  This document
   describes an inter-domain VPLS solution that provides PW node
   redundancy across domains.  The redundancy mechanism will provide
   node redundancy and link redundancy in both domains.  The domain in
   this document refers to autonomous system (AS), or other
   administrative domains.

   The solution relies on the use of Inter-Chassis Communication
   Protocol (ICCP) [I-D.ietf-pwe3-iccp] to coordinate between the two
   redundant edge nodes, and use of PW Preferential Forwarding Status
   Bit [RFC6870] to negotiate the PW status.  There is no change to any
   protocol message formats and no new protocol options are introduced.
   This solution is a description of reusing existing protocol building
   blocks to achieve the desired function, but also defines
   implementation behavior necessary for the function to work.

2.  Conventions used in this document

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in [RFC2119].

3.  Motivation

   Inter-AS VPLS offerings are widely deployed in service provider
   networks today.  Typically, the Autonomous System Border Router
   (ASBR) and associated physical links that connect the domains carry a
   multitude of services.  As such, it is important to provide link and
   node redundancy, to ensure service high availability and meet the end
   customer service level agreements (SLAs).

   Several current deployments of inter-AS VPLS are implemented like
   inter-AS option A in [RFC4364] section 10, where Virtual Local Area
   Network (VLAN) is used to hand-off the services between two domains.
   In these deployments, link/node redundancy is achieved using Multi-
   Chassis Link Aggregation (MC-LAG) and ICCP [I-D.ietf-pwe3-iccp].
   This, however, places two restrictions on the interconnection: the
   two domains must be interconnected using Ethernet links, and the
   links must be homogeneous, i.e. of the same speed, in order to be
   aggregated.  These two conditions can not always be guaranteed in

Liu, et al.             Expires October 26, 2014                [Page 3]
Internet-Draft      Redundancy for VPLS Inter-domain          April 2014

   live deployments.  For instance, there are many scenarios where the
   interconnection between the domains uses Packet over Synchronous
   Optical Networking (SONET) / Synchronous Digital Hierarchy (SDH),
   thereby ruling out the applicability of MC-LAG as a redundancy
   mechanism.  As such, from a technical point of view, it is desirable
   to use PWs to interconnect the VPLS domains, and to offer resiliency
   using PW redundancy mechanisms.

   Multiprotocol Border Gateway Protocol (MP-BGP) can be used for VPLS
   inter-domain protection, as described in [RFC6074], using either
   option B or option C inter-AS models.  However, with this solution,
   the protection time relies on BGP control plane convergence.  In
   certain deployments, with tight SLA requirements on availability,
   this mechanism may not provide the desired failover time
   characteristics.  Furthermore, in certain situations MP-BGP is not
   deployed for VPLS.  The redundancy solution described in this
   document reuses ICCP [I-D.ietf-pwe3-iccp] and PW redundancy [RFC6718]
   to provide fast convergence.

   Furthermore, in the case where Label Switched Multicast is not used
   for VPLS multicast [RFC7117], the solution described here provides a
   better behavior compared to inter-AS option B: with option B, each
   Provider Edge (PE) must perform ingress replication to all other PEs
   in its local as well as the remote domain.  Whereas, with the ICCP
   solution, the PE only replicates to local PEs and to the ASBR.  The
   ASBR then sends traffic point-to-point to the remote ASBR, and the
   remote ASBR replicates to its local PEs.  As a result, the load of
   replication is distributed and is more efficient than option B.

   Two PW redundancy modes defined in [RFC6718], namely independent mode
   and master/slave mode, are applicable in this solution.  In order to
   maintain control plane separation between two domains, the
   independent mode is preferred by operators.  The master/slave mode
   provides some enhanced capabilities and, hence, is included in this
   document.

4.  Network Use Case

   There are two network use cases for VPLS inter-domain redundancy:
   two-PWs redundancy case, and four-PWs redundancy case.

   Figure 1 presents an example use case with two inter-domain PWs.
   PE3/PE4/PE5/PE6 may be ASBRs of their respective AS, or VPLS PEs
   within its own AS.  PE3 and PE4 belong to one redundancy group (RG),
   and PE5 and PE6 belong to another RG.  A deployment example of this
   use case is where there are only two physical links between two
   domains and PE3 is physically connected with PE5, and PE4 is

Liu, et al.             Expires October 26, 2014                [Page 4]
Internet-Draft      Redundancy for VPLS Inter-domain          April 2014

   physically connected with PE6.

                 +---------+                 +---------+
         +---+   | +-----+ |   active PW1    |  +-----+|    +---+
         |PE1|---|-| PE3 |-|-----------------|--| PE5 ||----|PE7|
         +---+\  |/+-----+ |                 |  +-----+\   /+---+
          |    \ /  | *    |                 |    * |  |\ /   |
          |     \|  | |ICCP|                 |ICCP| |  | \    |
          |    / \  | *    |                 |    * |  |/ \   |
         +---+/  |\+-----+ |                 |  +-----+/   \+---+
         |PE2|---|-| PE4 |-|-----------------|--| PE6 ||----|PE8|
         +---+   | +-----+ |   standby PW2   |  +-----+|    +---+
                 |         |                 |         |
                 |         |                 |         |
                 |  RG1    |                 |  RG2    |
                 +---------+                 +---------+
                 operator A network             operator B network

                                 Figure 1

   Figure 2 presents a four-PWs inter-domain VPLS redundancy use case.
   PE3/PE4/PE5/PE6 may be ASBRs of their respective AS, or VPLS PEs
   within its own AS.  A deployment example of this use case is where
   there are four physical links between two domains and four PEs are
   physically connected with each other with four links.

                  +---------+                 +---------+
          +---+   | +-----+ |                 |  +-----+|    +---+
          |PE1|---|-| PE3 |-|--------PW1------|--| PE5 ||----|PE7|
          |   |   | |     |-|-PW3\     /------|--|     ||    |   |
          +---+\  |/+-----+ |     \   /       |  +-----+\   /+---+
           |    \ /  | *    |      \ /        |    * |  |\ /   |
           |     \|  | |ICCP|       X         |ICCP| |  | \    |
           |    / \  | *    |      / \        |    * |  |/ \   |
          +---+/  |\+-----+ |     /   \       |  +-----+/   \+---+
          |   |   | |     |-|-PW4/     \------|--|     ||    |   |
          |PE2|---|-| PE4 |-|----PW2----------|--| PE6 ||----|PE8|
          +---+   | +-----+ |                 |  +-----+|    +---+
                  |         |                 |         |
                  |         |                 |         |
                  |  RG1    |                 |  RG2    |
                  +---------+                 +---------+
                operator A network         operator B network

Liu, et al.             Expires October 26, 2014                [Page 5]
Internet-Draft      Redundancy for VPLS Inter-domain          April 2014

                                 Figure 2

5.   PW redundancy application procedure for inter-domain redundancy

   PW redundancy application procedures are described in section 9.1 of
   [I-D.ietf-pwe3-iccp].  When a PE node encounters a failure, the other
   PE takes over.  This document reuses the PW redundancy mechanism
   defined in[I-D.ietf-pwe3-iccp], with new ICCP switchover conditions
   as specified in following section.

   There are two PW redundancy modes defined in [RFC6870]: Independent
   mode and Master/Slave mode.  For the inter-domain four-PW scenario,
   it is required for PEs to ensure that the same mode is supported on
   the two ICCP peers in the same RG.  This can be achieved using manual
   configuration at the ICCP peers.  Other methods for ensuring
   consistency are out of the scope of this document.

5.1.  ICCP switchover condition

5.1.1.  Inter-domain PW failure

   When a PE receives advertisements from the active PE, in the same RG,
   indicating that all the inter-domain PW status has changed to DOWN/
   STANDBY, then if it has the highest priority (after the advertising
   PE), it SHOULD advertise active state for all of its associated
   inter-domain PWs.

5.1.2.  PE node isolation

   When a PE detects failure of all PWs to the local domain, it SHOULD
   advertise standby state for all its inter-domain PWs to trigger
   remote PE to switchover.

5.1.3.  PE node failure

   When a PE node detects that the active PE, that is a member of the
   same RG, has gone down, if the local PE has redundant PWs for the
   affected services and has the highest priority (after the failed PE),
   it SHOULD advertise the active state for all associated inter-domain
   PWs.

5.2.  Inter-domain redundancy with two-PWs

   In this use case, it is recommended that the operation be as follows:
   o  ICCP deployment option: ICCP is deployed on VPLS edge nodes in
      both domains;

Liu, et al.             Expires October 26, 2014                [Page 6]
Internet-Draft      Redundancy for VPLS Inter-domain          April 2014

   o  PW redundancy mode: independent mode only;
   o  Protection architectures: 1:1(1 standby, 1 active).

   The switchover rules described in section 5.1 apply.  Before
   deploying this inter-domain VPLS, the operators should negotiate to
   configure the same PW high/low priority at two PW end-points.  The
   inter-domain VPLS relationship normally involves a contractual
   process between operators, and the configuration of PW roles forms
   part of this process.  E.g, in figure 1, PE3 and PE5 must both have
   higher/lower priority than PE4 and PE6, otherwise both PW1 and PW2
   will be in standby state.

5.3.  Inter-domain redundancy with four-PWs

   In this use case, there are two options to provide protection: 1:1
   and 3:1 protection.  The inter-domain PWs that connect to the same PE
   should have proper PW priority to advertise same active/standby
   state.  E.g, in figure 2, both PW1 and PW3 connected to PE3 should
   advertise active/standby state.

   For 1:1 protection model, the operation would be as follows:
   o  ICCP deployment option: ICCP is deployed on VPLS edge nodes in
      both domains;
   o  PW redundancy mode: independent mode only;
   o  Protection architectures: 1:1(1 standby, 1 active).

   The switchover rules described in section 5.1 apply.  In this case,
   the operators do not need to do any coordination of the inter-domain
   PW priority.  The PE detecting one PW DOWN SHOULD set the other PW to
   STANDBY if available, and then synchronize the updated state to its
   ICCP peer.  When a PE detects that the PWs from ICCP peer PE are DOWN
   or STANDBY, it SHOULD switchover as described in section 5.1.1.

   There are two variants of the 3:1 protection model.  We will refer to
   them as options A and B. The implementation MUST support option A,
   and MAY support option B. Option B will be useful when the two legacy
   PEs in one domain does not support the function in this document.
   The two legacy PEs still need to support PW redundancy defined in
   [RFC6870], and be configured as slave node.

   For option A of the 3:1 protection model, the support of Request
   Switchover status bit [RFC6870] is required.  The operation is as
   follows:
   o  ICCP deployment option: ICCP is deployed on VPLS edge nodes in
      both domains;
   o  PW redundancy mode: Independent mode with 'request switchover' bit
      support;

Liu, et al.             Expires October 26, 2014                [Page 7]
Internet-Draft      Redundancy for VPLS Inter-domain          April 2014

   o  Protection architectures: 3:1 (3 standby, 1 active).

   In this case, the procedure on the PE for the PW failure is per
   section 6.3 of [RFC6870], and with the following additions:
   o  When the PE detects failure of the active inter-domain PW, it
      SHOULD switch to the other local standby inter-domain PW if
      available, and send an updated LDP PW status message with the
      'request switchover' bit set on that local standby inter-domain PW
      to the remote PE;
   o  Local and remote PE SHOULD also update the new PW status to their
      ICCP peers, respectively, in Application Data Messages with PW-RED
      Synchronization Request TLV for corresponding service, so as to
      synchronize the latest PW status on both PE sides.
   o  While waiting for the acknowledgement, the PE that sends the
      'request switchover' bit may receive a switchover request from its
      ICCP peer's PW remote endpoint by virtue of the ICCP
      synchronization.  The PE MUST compare IP addresses with that PW
      remote peer.  The PE with a higher IP address SHOULD ignore the
      request and continue to wait for the acknowledgement from its peer
      in the remote domain.  The PE with the lower IP address SHOULD
      clear 'request switchover' bit and set 'Preferential Forwarding'
      local status bit, and update the PW status to ICCP peer.
   o  The remote PE receiving 'request switchover' bit SHOULD
      acknowledge the request and activate the PW only when it is ready
      to take over as described in section 5.1, otherwise, it SHOULD
      ignore the request.

   The node isolation failure and node failure is described in section
   5.1.

   For option B of 3:1 protection model, master/slave mode support is
   required, and should be as follows:
   o  ICCP deployment option: ICCP is deployed on VPLS edge nodes in
      only one domain;
   o  PW redundancy mode: master/slave only;
   o  Protection architectures: 3:1 (3 standby, 1 active).

   When master/slave PW redundancy mode is employed, the network
   operators of two domains must agree on which domain PEs will be
   master, and configure the devices accordingly.  The inter-domain PWs
   that connect to one PE should have higher PW priority than the PWs on
   the other PE in the same RG.  The procedure on the PE for PW failure
   is as follows:
   o  The PE with higher PW priority should only enable one PW active,
      and the other PWs standby.
   o  When the PE detects active PW DOWN, it SHOULD enable the other
      local standby PW to be active with preference.  Only when two
      inter-domain PWs connect to the PE are DOWN, the ICCP peer PE in

Liu, et al.             Expires October 26, 2014                [Page 8]
Internet-Draft      Redundancy for VPLS Inter-domain          April 2014

      the same RG SHOULD switchover as described in section 5.1.

   The node isolation failure and node failure is described in section
   5.1.

6.  Management Considerations

   When deploying the inter-domain redundancy mechanism described in
   this document, consistent provisioning is required for proper
   operation.  The two domains must both use the same use case (section
   5.2 or section 5.3).  Within each section, all of the described modes
   and options must be provisioned identically both within each RG and
   between the RGs.  Additionally, for the two-PWs redundancy options
   defined in section 5.2, the two operators must also negotiate to
   configure same high/low PW priority at the two PW end-points.  If the
   provisioning is inconsistent, then the inter-domain redundancy
   mechanism may not work properly.

7.  Security Considerations

   Besides the security properties of [I-D.ietf-pwe3-iccp] for ICCP
   control plane, [RFC4762] and [RFC6870] for PW control plane, this
   document has additional security consideration for ICCP control
   plane.

   In this document, ICCP protocol is deployed between two PEs or ASBRs.
   The two PEs or ASBRs should only be connected by a well managed and
   highly monitored network.  This should be ensured by the operator.

   The state flapping on the inter-domain and intra-domain PW may cause
   security threats or be exploited to create denial of service attacks.
   For example, excessive PW state flapping (e.g., by malicious peer
   PE's implementation) may lead to excessive ICCP exchanges.
   Implementations SHOULD provide mechanisms to perform control-plane
   policing and mitigate such types of attacks.

8.  IANA Consideration

   No IANA allocation is required in this document.

9.  Acknowledgements

   The author would like to thank Sami Boutros, Giles Heron, Adrian
   Farrel, Andrew G. Malis and Stephen Kent for their valuable comments.

Liu, et al.             Expires October 26, 2014                [Page 9]
Internet-Draft      Redundancy for VPLS Inter-domain          April 2014

10.  Contributors

      Daniel Cohn

      Email:daniel.cohn.ietf@gmail.com

      Yubao Wang
      ZTE Corporation
      Nanjing, China
      Email: wang.yubao@zte.com.cn

11.  References

11.1.  Normative references

   [I-D.ietf-pwe3-iccp]
              Martini, L., Salam, S., Sajassi, A., and S. Matsushima,
              "Inter-Chassis Communication Protocol for L2VPN PE
              Redundancy", draft-ietf-pwe3-iccp-16 (work in progress),
              March 2014.

   [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
              Requirement Levels", BCP 14, RFC 2119, March 1997.

   [RFC6870]  Muley, P. and M. Aissaoui, "Pseudowire Preferential
              Forwarding Status Bit", RFC 6870, February 2013.

11.2.  Informative references

   [RFC4364]  Rosen, E. and Y. Rekhter, "BGP/MPLS IP Virtual Private
              Networks (VPNs)", RFC 4364, February 2006.

   [RFC4762]  Lasserre, M. and V. Kompella, "Virtual Private LAN Service
              (VPLS) Using Label Distribution Protocol (LDP) Signaling",
              RFC 4762, January 2007.

   [RFC6074]  Rosen, E., Davie, B., Radoaca, V., and W. Luo,
              "Provisioning, Auto-Discovery, and Signaling in Layer 2
              Virtual Private Networks (L2VPNs)", RFC 6074,
              January 2011.

   [RFC6718]  Muley, P., Aissaoui, M., and M. Bocci, "Pseudowire
              Redundancy", RFC 6718, August 2012.

   [RFC7117]  Aggarwal, R., Kamite, Y., Fang, L., Rekhter, Y., and C.
              Kodeboniya, "Multicast in Virtual Private LAN Service
              (VPLS)", RFC 7117, February 2014.

Liu, et al.             Expires October 26, 2014               [Page 10]
Internet-Draft      Redundancy for VPLS Inter-domain          April 2014

Authors' Addresses

   Zhihua Liu
   China Telecom
   109 Zhongshan Ave.
   Guangzhou 510630
   P.R.China

   Email: zhliu@gsta.com

   Lizhong Jin
   Shanghai
   P.R.China

   Email: lizho.jin@gmail.com

   Ran Chen
   ZTE Corporation
   NO.19 East Huayuan Road
   Haidian District Beijing 100191
   P.R.China

   Email: chen.ran@zte.com.cn

   Dennis Cai
   Cisco
   3750 Cisco Way,
   San Jose, California 95134
   USA

   Email: dcai@cisco.com

   Samer Salam
   Cisco
   595 Burrard Street, Suite:2123
   Vancouver, BC V7X 1J1
   Canada

   Email: ssalam@cisco.com

Liu, et al.             Expires October 26, 2014               [Page 11]