draft-hu-bier-oam-yang-01.txt:
xym 0.4:
Extracting 'ietf-bier-oam@2017-06-13.yang'
Removed 0 empty lines
ietf-bier-oam@2016-12-05.yang:
pyang 1.7.3: pyang --verbose --ietf -p {libs} {model}:
ietf-bier-oam@2016-12-05.yang:1: warning: unexpected latest revision "2017-06-12" in ietf-bier-oam@2016-12-05.yang, should be 2016-12-05
ietf-bier-oam@2016-12-05.yang:43: warning: the revision statements are not given in reverse chronological order
ietf-bier-oam@2016-12-05.yang:52: error: ietf-bier:bier in the path for bier-bsl at ietf-bier-oam@2016-12-05.yang:82 is not found
ietf-bier-oam@2016-12-05.yang:52: error: ietf-bier:bier in the path for bier-bsl at ietf-bier-oam@2016-12-05.yang:50 is not found
ietf-bier-oam@2016-12-05.yang:59: error: ietf-bier:bier in the path for bier-subdomainid at ietf-bier-oam@2016-12-05.yang:87 is not found
ietf-bier-oam@2016-12-05.yang:59: error: ietf-bier:bier in the path for bier-subdomainid at ietf-bier-oam@2016-12-05.yang:57 is not found
ietf-bier-oam@2016-12-05.yang:66: error: ietf-bier:bier in the path for bier-bfrid at ietf-bier-oam@2016-12-05.yang:92 is not found
ietf-bier-oam@2016-12-05.yang:66: error: ietf-bier:bier in the path for bier-bfrid at ietf-bier-oam@2016-12-05.yang:64 is not found
ietf-bier-oam@2016-12-05.yang:73: error: identity "tp-address-type" not found in module ietf-connectionless-oam
ietf-bier-oam@2016-12-05.yang:78: error: node ietf-connectionless-oam::location-type is not found
ietf-bier-oam@2016-12-05.yang:105: error: node ietf-connectionless-oam::location-type is not found
yanglint 0.13.79: yanglint --verbose -p {rfclib} -p {draftlib} -p {tmplib} {model} -i:
err : Failed to resolve identity "ietf-connectionless-oam:tp-address-type".
err : No resolvents found for leafref "/ietf-bier:bier/ietf-bier:bier-global/ietf-bier:sub-domain/ietf-bier:bitstringlength". (/ietf-network:networks/ietf-network:network/ietf-network:node/ietf-connectionless-oam:location-type/ietf-connectionless-oam:ip-prefix-location-type/ietf-connectionless-oam:test-point-ip-prefix-location-list/ietf-connectionless-oam:test-point-locations/bier-test-point-location-list/test-point-locations/bier-bsl)
err : No resolvents found for leafref "/ietf-bier:bier/ietf-bier:bier-global/ietf-bier:sub-domain/ietf-bier:sub-domain-id". (/ietf-network:networks/ietf-network:network/ietf-network:node/ietf-connectionless-oam:location-type/ietf-connectionless-oam:ip-prefix-location-type/ietf-connectionless-oam:test-point-ip-prefix-location-list/ietf-connectionless-oam:test-point-locations/bier-test-point-location-list/test-point-locations/bier-subdomainid)
err : No resolvents found for leafref "/ietf-bier:bier/ietf-bier:bier-global/ietf-bier:sub-domain/ietf-bier:bfr-id". (/ietf-network:networks/ietf-network:network/ietf-network:node/ietf-connectionless-oam:location-type/ietf-connectionless-oam:ip-prefix-location-type/ietf-connectionless-oam:test-point-ip-prefix-location-list/ietf-connectionless-oam:test-point-locations/bier-test-point-location-list/test-point-locations/bier-bfrid)
err : Failed to resolve augment "/ietf-network:networks/ietf-network:network/ietf-network:node/ietf-connectionless-oam:location-type/ietf-connectionless-oam:ip-prefix-location-type/ietf-connectionless-oam:test-point-ip-prefix-location-list/ietf-connectionless-oam:test-point-locations". (/ietf-bier-oam:{augment}[/ietf-network:networks/ietf-network:network/ietf-network:node/ietf-connectionless-oam:location-type/ietf-connectionless-oam:ip-prefix-location-type/ietf-connectionless-oam:test-point-ip-prefix-location-list/ietf-connectionless-oam:test-point-locations])
err : Failed to resolve augment "/ietf-network:networks/ietf-network:network/ietf-network:node/ietf-connectionless-oam:location-type/ietf-connectionless-oam:ip-prefix-location-type/ietf-connectionless-oam:test-point-ip-prefix-location-list/ietf-connectionless-oam:test-point-locations/ietf-connectionless-oam:technology". (/ietf-bier-oam:{augment}[/ietf-network:networks/ietf-network:network/ietf-network:node/ietf-connectionless-oam:location-type/ietf-connectionless-oam:ip-prefix-location-type/ietf-connectionless-oam:test-point-ip-prefix-location-list/ietf-connectionless-oam:test-point-locations/ietf-connectionless-oam:technology])
err : Module "ietf-bier-oam" parsing failed.